The CFD is developed as a special equipment of the fly ash feeder to be attached under the cooling tower in the incineration facility and/or the dust collector.
In that ease, the internal temperature of the equipment reaches 300-360 degrees Celsius.
In this application, the maximum internal temperature of the equipment reaches 900 degrees Celsius because it is attached under the secondary combustion chamber.
For this reason, not only is the drive shaft cooled but the shaft mount as well.
Furthermore, the rotary vanes and the drive shaft are manufactured with SS310S which has beneficial effects on the heat resistance.
キーワード
Heat Resistant Specs
Garbage / Trash
Slag. Metal
Fusion Furnace
Secondary Combustion Chamber 900°C Deg
Fuel Oil
Cooling Tower
Bag Filter
Water
Storage Tank
for
Fly Ash
The CFD is developed as a special equipment of the fly ash feeder
to be attached under the cooling tower in the incineration facility and/or the dust collector.
In that ease, the internal temperature of the equipment reaches 300-360 degrees Celsius.
In this application, the maximum internal temperature of the equipment reaches
900 degrees Celsius because it is attached under the secondary combustion chamber.
For this reason, not only is the drive shaft cooled but the shaft mount as well.
Furthermore, the rotary vanes and the drive shaft are manufactured with SS310S which has beneficial effects on the heat resistance.
A-21
D Series CFD-2200
-Pouring Water
Water Discharge Water Discharge
-Pouring Water
Chain Conveyor
Pouring Wate Water Discharge Water Discharge -Pouring Wate
Circle Feeder CF-1000A-CV
Kneader
Recycling for Filling in Land, Road Bed Agent and etc.
YOSHIKAWA Corporation
Please feel free to contact us for a consultation, inquiry, or request for a quotation regarding our products. We also accept inquiries by phone or fax.
TEL/+81-996-26-3388 FAX/+81-996-26-3688
Phone inquiry hours: 8:30 a.m. to 5:00 p.m. Japan time
(except Saturdays and Sundays)
Fax inquiries can be received at any hour.